SMART рапортирует о том, что Reallocated Sector Count осталось существенно мало.
Детали:
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar T7K500
Device Model: Hitachi HDT725032VLA360
Serial Number: VFD200R21JGX5C
LU WWN Device Id: 5 000cca 311d59568
Firmware Version: V54OA73A
User Capacity: 320,071,851,520 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
Local Time is: Tue Nov 8 23:44:07 2011 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5601) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 94) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 099 099 016 Pre-fail Always - 2
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 113 113 024 Pre-fail Always - 334 (Average 324)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 612
5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 1884
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 3351
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 558
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 716
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 716
194 Temperature_Celsius 0x0002 166 166 000 Old_age Always - 36 (Min/Max 14/63)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 2204
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 3
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always - 12
SMART Error Log Version: 1
ATA Error Count: 1940 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1940 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 29 16 23 8d e2 Error: UNC at LBA = 0x028d2316 = 42803990
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 00 3f 22 8d e2 00 01:35:37.400 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:32.600 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:27.800 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:23.000 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:18.200 READ VERIFY SECTOR(S)
Error 1939 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 29 16 23 8d e2 Error: UNC at LBA = 0x028d2316 = 42803990
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 00 3f 22 8d e2 00 01:35:32.600 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:27.800 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:23.000 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:18.200 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:13.500 READ VERIFY SECTOR(S)
Error 1938 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 29 16 23 8d e2 Error: UNC at LBA = 0x028d2316 = 42803990
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 00 3f 22 8d e2 00 01:35:27.800 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:23.000 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:18.200 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:13.500 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
Error 1937 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 29 16 23 8d e2 Error: UNC at LBA = 0x028d2316 = 42803990
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 00 3f 22 8d e2 00 01:35:23.000 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:18.200 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:13.500 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
40 00 00 3f 20 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
Error 1936 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 29 16 23 8d e2 Error: UNC at LBA = 0x028d2316 = 42803990
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
40 00 00 3f 22 8d e2 00 01:35:18.200 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:13.500 READ VERIFY SECTOR(S)
40 00 00 3f 22 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
40 00 00 3f 20 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
40 00 00 3f 1e 8d e2 00 01:35:08.700 READ VERIFY SECTOR(S)
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3351 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.