Hitachi 320 Gb (with SMART problems)

Продам SATA винчестер Hitachi объемом 320 Gb.

Цена: 100 грн

SMART рапортирует о том, что Reallocated Sector Count осталось существенно мало.

 

Детали:

=== START OF INFORMATION SECTION ===

Model Family:     Hitachi Deskstar T7K500

Device Model:     Hitachi HDT725032VLA360

Serial Number:    VFD200R21JGX5C

LU WWN Device Id: 5 000cca 311d59568

Firmware Version: V54OA73A

User Capacity:    320,071,851,520 bytes [320 GB]

Sector Size:      512 bytes logical/physical

Device is:        In smartctl database [for details use: -P show]

ATA Version is:   7

ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1

Local Time is:    Tue Nov  8 23:44:07 2011 EET

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

 

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: FAILED!

Drive failure expected in less than 24 hours. SAVE ALL DATA.

See vendor-specific Attribute list for failed Attributes.

 

General SMART Values:

Offline data collection status:  (0x00) Offline data collection activity

was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status:      (   0) The previous self-test routine completed

without error or no self-test has ever 

been run.

Total time to complete Offline 

data collection: ( 5601) seconds.

Offline data collection

capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

No Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities:            (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability:        (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine 

recommended polling time: (   1) minutes.

Extended self-test routine

recommended polling time: (  94) minutes.

SCT capabilities:       (0x003f) SCT Status supported.

SCT Error Recovery Control supported.

SCT Feature Control supported.

SCT Data Table supported.

 

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE

  1 Raw_Read_Error_Rate     0x000b   099   099   016    Pre-fail  Always       -       2

  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0

  3 Spin_Up_Time            0x0007   113   113   024    Pre-fail  Always       -       334 (Average 324)

  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       612

  5 Reallocated_Sector_Ct   0x0033   001   001   005    Pre-fail  Always   FAILING_NOW 1884

  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0

  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0

  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       3351

 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0

 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       558

192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       716

193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       -       716

194 Temperature_Celsius     0x0002   166   166   000    Old_age   Always       -       36 (Min/Max 14/63)

196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       2204

197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       3

198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0

199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       12

 

SMART Error Log Version: 1

ATA Error Count: 1940 (device log contains only the most recent five errors)

CR = Command Register [HEX]

FR = Features Register [HEX]

SC = Sector Count Register [HEX]

SN = Sector Number Register [HEX]

CL = Cylinder Low Register [HEX]

CH = Cylinder High Register [HEX]

DH = Device/Head Register [HEX]

DC = Device Command Register [HEX]

ER = Error register [HEX]

ST = Status register [HEX]

Powered_Up_Time is measured from power on, and printed as

DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,

SS=sec, and sss=millisec. It "wraps" after 49.710 days.

 

Error 1940 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)

  When the command that caused the error occurred, the device was active or idle.

 

  After command completion occurred, registers were:

  ER ST SC SN CL CH DH

  -- -- -- -- -- -- --

  40 51 29 16 23 8d e2  Error: UNC at LBA = 0x028d2316 = 42803990

 

  Commands leading to the command that caused the error were:

  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name

  -- -- -- -- -- -- -- --  ----------------  --------------------

  40 00 00 3f 22 8d e2 00      01:35:37.400  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:32.600  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:27.800  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:23.000  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:18.200  READ VERIFY SECTOR(S)

 

Error 1939 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)

  When the command that caused the error occurred, the device was active or idle.

 

  After command completion occurred, registers were:

  ER ST SC SN CL CH DH

  -- -- -- -- -- -- --

  40 51 29 16 23 8d e2  Error: UNC at LBA = 0x028d2316 = 42803990

 

  Commands leading to the command that caused the error were:

  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name

  -- -- -- -- -- -- -- --  ----------------  --------------------

  40 00 00 3f 22 8d e2 00      01:35:32.600  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:27.800  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:23.000  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:18.200  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:13.500  READ VERIFY SECTOR(S)

 

Error 1938 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)

  When the command that caused the error occurred, the device was active or idle.

 

  After command completion occurred, registers were:

  ER ST SC SN CL CH DH

  -- -- -- -- -- -- --

  40 51 29 16 23 8d e2  Error: UNC at LBA = 0x028d2316 = 42803990

 

  Commands leading to the command that caused the error were:

  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name

  -- -- -- -- -- -- -- --  ----------------  --------------------

  40 00 00 3f 22 8d e2 00      01:35:27.800  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:23.000  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:18.200  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:13.500  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

 

Error 1937 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)

  When the command that caused the error occurred, the device was active or idle.

 

  After command completion occurred, registers were:

  ER ST SC SN CL CH DH

  -- -- -- -- -- -- --

  40 51 29 16 23 8d e2  Error: UNC at LBA = 0x028d2316 = 42803990

 

  Commands leading to the command that caused the error were:

  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name

  -- -- -- -- -- -- -- --  ----------------  --------------------

  40 00 00 3f 22 8d e2 00      01:35:23.000  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:18.200  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:13.500  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

  40 00 00 3f 20 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

 

Error 1936 occurred at disk power-on lifetime: 2424 hours (101 days + 0 hours)

  When the command that caused the error occurred, the device was active or idle.

 

  After command completion occurred, registers were:

  ER ST SC SN CL CH DH

  -- -- -- -- -- -- --

  40 51 29 16 23 8d e2  Error: UNC at LBA = 0x028d2316 = 42803990

 

  Commands leading to the command that caused the error were:

  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name

  -- -- -- -- -- -- -- --  ----------------  --------------------

  40 00 00 3f 22 8d e2 00      01:35:18.200  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:13.500  READ VERIFY SECTOR(S)

  40 00 00 3f 22 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

  40 00 00 3f 20 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

  40 00 00 3f 1e 8d e2 00      01:35:08.700  READ VERIFY SECTOR(S)

 

SMART Self-test log structure revision number 1

Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error

# 1  Short offline       Completed without error       00%      3351         -

 

SMART Selective self-test log data structure revision number 1

 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS

    1        0        0  Not_testing

    2        0        0  Not_testing

    3        0        0  Not_testing

    4        0        0  Not_testing

    5        0        0  Not_testing

Selective self-test flags (0x0):

  After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.