2x Hitachi 320Gb

Продаю 2 SATA винчестера Hitachi 320 Gb из одной серии.

Идеально подойдут для использования в RAID.

Цена (за пару): 500грн

Детали по первому:

=== START OF INFORMATION SECTION ===

Model Family:     Hitachi Deskstar T7K500

Device Model:     Hitachi HDT725032VLA360

Serial Number:    VFM201R808EW4N

LU WWN Device Id: 5 000cca 317c3d70e

Firmware Version: V54OA7EA

User Capacity:    320,072,933,376 bytes [320 GB]

Sector Size:      512 bytes logical/physical

Device is:        In smartctl database [for details use: -P show]

ATA Version is:   7

ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1

Local Time is:    Wed Nov  9 00:06:20 2011 EET

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

 

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

 

General SMART Values:

Offline data collection status:  (0x00) Offline data collection activity

was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status:      (   0) The previous self-test routine completed

without error or no self-test has ever 

been run.

Total time to complete Offline 

data collection: ( 5601) seconds.

Offline data collection

capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

No Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities:            (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability:        (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine 

recommended polling time: (   1) minutes.

Extended self-test routine

recommended polling time: (  94) minutes.

SCT capabilities:       (0x003f) SCT Status supported.

SCT Error Recovery Control supported.

SCT Feature Control supported.

SCT Data Table supported.

 

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE

  1 Raw_Read_Error_Rate     0x000b   090   090   016    Pre-fail  Always       -       1048626

  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0

  3 Spin_Up_Time            0x0007   113   113   024    Pre-fail  Always       -       330 (Average 332)

  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       1279

  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       45

  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0

  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0

  9 Power_On_Hours          0x0012   099   099   000    Old_age   Always       -       11673

 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0

 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       1249

192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always       -       1705

193 Load_Cycle_Count        0x0012   099   099   000    Old_age   Always       -       1705

194 Temperature_Celsius     0x0002   230   230   000    Old_age   Always       -       26 (Min/Max 13/57)

196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       55

197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0

198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0

199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       0

 

SMART Error Log Version: 1

No Errors Logged

 

SMART Self-test log structure revision number 1

Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error

# 1  Short offline       Completed without error       00%     11673         -

 

SMART Selective self-test log data structure revision number 1

 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS

    1        0        0  Not_testing

    2        0        0  Not_testing

    3        0        0  Not_testing

    4        0        0  Not_testing

    5        0        0  Not_testing

Selective self-test flags (0x0):

  After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

 

 

Детали по второму:

=== START OF INFORMATION SECTION ===

Model Family:     Hitachi Deskstar T7K500

Device Model:     Hitachi HDT725032VLA360

Serial Number:    VFM201R8089H2N

LU WWN Device Id: 5 000cca 317c3c694

Firmware Version: V54OA7EA

User Capacity:    320,072,933,376 bytes [320 GB]

Sector Size:      512 bytes logical/physical

Device is:        In smartctl database [for details use: -P show]

ATA Version is:   7

ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 1

Local Time is:    Wed Nov  9 00:13:15 2011 EET

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

 

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

 

General SMART Values:

Offline data collection status:  (0x00) Offline data collection activity

was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status:      (   0) The previous self-test routine completed

without error or no self-test has ever 

been run.

Total time to complete Offline 

data collection: ( 5601) seconds.

Offline data collection

capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

No Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities:            (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability:        (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine 

recommended polling time: (   1) minutes.

Extended self-test routine

recommended polling time: (  94) minutes.

SCT capabilities:       (0x003f) SCT Status supported.

SCT Error Recovery Control supported.

SCT Feature Control supported.

SCT Data Table supported.

 

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE

  1 Raw_Read_Error_Rate     0x000b   095   095   016    Pre-fail  Always       -       720900

  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0

  3 Spin_Up_Time            0x0007   115   115   024    Pre-fail  Always       -       326 (Average 326)

  4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       -       1283

  5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       -       21

  7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       -       0

  8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      -       0

  9 Power_On_Hours          0x0012   099   099   000    Old_age   Always       -       11673

 10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       -       0

 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       1253

192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always       -       1710

193 Load_Cycle_Count        0x0012   099   099   000    Old_age   Always       -       1710

194 Temperature_Celsius     0x0002   230   230   000    Old_age   Always       -       26 (Min/Max 13/56)

196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       28

197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       -       0

198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      -       0

199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       -       0

 

SMART Error Log Version: 1

No Errors Logged

 

SMART Self-test log structure revision number 1

Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error

# 1  Short offline       Completed without error       00%     11673         -

 

SMART Selective self-test log data structure revision number 1

 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS

    1        0        0  Not_testing

    2        0        0  Not_testing

    3        0        0  Not_testing

    4        0        0  Not_testing

    5        0        0  Not_testing

Selective self-test flags (0x0):

  After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.